Free shipping in the US only on this deal
Shop now as product availability changes daily
nutribullet Ultra Plus Kitchen System - Matte White
Advance your culinary capabilities with the nutribullet® Ultra Plus+ Compact Kitchen System. This 3-in-1 set uses the nutribullet® Ultra Motor Base to power personal blending, food processor, and coffee & spice grinder attachments, delivering full-kitchen functionality within one space-saving design.
- Personal Blender. Two Tritan Renew blending cups and the ultra-durable Rapid Extractor Blade allow you to make delicious smoothies and more.
- Food Processor. Quickly chops, slices, and shreds a wide array of ingredients for unlimited culinary creations.
- Coffee & Spice Grinder. Efficiently grinds coffee beans, spices, and herbs for superior flavor and potency.
- Blending, illuminated. A glow interface illuminates two blending options as soon as your attachment meets the Motor Base. Choose the full circle for the automated cycle, or the pulse circle for hands-on control.
-
Sleek silhouette. A streamlined profile takes up minimal space on the kitchen counter and brings innovative design into your home.
- Dimensions - 5" L x 4.75" W x 14"H
Includes:
- (1) 1200W Motor Base
- (1) Rapid Extractor Blade made with Titanium-coated stainless steel
- (1) 32oz Blending Cup
- (1) 24oz Double Walled Blending Cup
- (2) To-Go Lids
- (1) Coffee & Spice Grinder Flat Blade
- (1) Coffee & Spice Grinder Cup
- (1) 2-Cup Food Processor Bowl
- (1) Reversible Slice/Shred Disc
- (1) Chopping Blade
- (1) Recipe Guide
How to Use:
Blender
- Place the Motor Base on a clean, dry, level surface such as a counter or table.
- Add ingredients and liquid to the nutribullet® Cup.
- Twist the Rapid Extractor Blade onto the nutribullet® Cup until it’s tightly sealed.
- Plug the Motor Base’s Power Cord into an electrical outlet.
- Flip the Cup downward and set it onto the Motor Base .
- Twist the Cup clockwise onto the Motor Base to lock it into place. (A “click” signals that the Cup is locked.) This will illuminate the Control Panel .
- Pressing the Solid Circle will start an automated blending cycle. When the blending cycle is activated, it will automatically stop after 30 seconds. Pressing and holding the Dashed Circle will pulse blend your ingredients. Release the Dashed Circle to stop blending.
- Twist the Cup counterclockwise to unlock and remove it from the Motor Base. You will hear a “click” when the Cup unlocks. Enjoy!
WARNING! NEVER blend hot, warm, or carbonated ingredients or liquid in the nutribullet ® Cup! Such use may over-pressurize the nutribullet ® Cup, causing the Cup to separate violently when removed from the Motor Base or opened, which may result in bodily injury from the hot contents or exposed blades.
NEVER apply heat or force, or attempt to pry apart the Cup from the Rapid Extractor Blade. Doing so may crack or shatter the Cup resulting in severe bodily injury. Allow the contents of the Cup to settle down for at least 30 minutes before attempting to open again. If still unable to open, contact Customer Service
Processor Attachment
- Place the Motor Base, Work Bowl, and Processor Base & Blade Adapter on a flat clean and dry surface.
- Remove the Work Bowl Lid from the Work Bowl, and slide the Work Bowl over the Processor Base & Blade Adapter. Turn the Work Bowl so that the bowl sits flush. The handle of the Work Bowl should sit opposite of the lid-locking mechanism on the Processor Base & Blade Adapter. Twist the Work Bowl clockwise to lock onto the Processor Base & Blade Adapter.
- Lower the Chopping Blade atop the central shaft of the Work Bowl and push down to secure into place. WARNING: The blades are sharp, handle with care.
- Prepare ingredients and add them to the Work Bowl. Remove seeds, stems, and other non-edible pieces. Cut large items into 1-to-2-inch pieces before processing.
- Place the Work Bowl & Processor Base onto the unplugged Motor Base. With the Work Bowl handle facing to the right side of the Motor Base, lower the Work Bowl onto the Motor Base and turn clockwise. The Processor Base will click when locked into place.
- Attach the Work Bowl Lid. Place the Work Bowl Lid on top of the Work Bowl and align the locking tab with the locking mechanism on the Processor Base & Blade Adapter. Push the Work Bowl Lid down while twisting clockwise to lock the lid into place. Plug in the Motor Base. The control panel will illuminate. The Processor Attachment will not work unless both the Processor Base and Work Bowl Lid are properly locked into place.
- Choose your processing method: press the Solid Circle to begin an automated processing cycle of 30 seconds, or press and hold the Dashed Circle for your desired amount of time to pulse or process manually.
- You may pour liquid through the top chute ONLY when the Processor Attachment is powered off and the blades are at a complete stop. (DO NOT fill ingredients beyond the Work Bowl’s MAX line).
- After processing, wait until the blades have come to a complete stop before attempting to remove the food.
Coffee & Spice Grinder Attachment
- Place the nutribullet® Ultra Plus+ Motor Base on a clean, dry, and level surface. Ensure that it is plugged in and powered on.
- Open the Grinder by twisting the Grinding Cup clockwise. Open the Grinder by twisting the Lid.
- Add ingredients to the Grinding Cup. DO NOT exceed the MAX line.
WARNING: Do not overfill the Grinder. Overfilling may prevent the blades from spinning freely, causing the Motor Base to overheat and thereby engaging the thermal safety breaker. If the Motor Base comes to an unprompted stop at any point, this likely indicates that the motor has overheated. Wait for the Motor Base to cool down (approximately 15 minutes), then resume use.
- Secure the Grinding Cup onto the Grinder Blade, then place it onto the Motor Base
- Twist the Grinder clockwise until it locks (“clicks”) into place. This will illuminate the Control Panel.
- For best results, grind ingredients using short 1-to-2 second pulses until reaching your desired consistency. To pulse ingredients, press and hold the Dashed Circle on the front of the Motor Base for your desired grinding time. Release your finger from the Dashed Circle to stop the grinding process.
- Once the grinding process has stopped, unlock the Grinder Attachment by twisting counter-clockwise.
- Detach the Grinder from the Motor Base. Open the Grinding Cup to access your ingredients.
- Remove the plug from the outlet and store your nutribullet® Ultra Plus+ safely, making sure that the cord is not left hanging over the edge of a table or counter, or touching any hot surfaces.
Care Instructions:
- Always power off and unplug your nutribullet ® Ultra Plus+ when not in use or when assembling, disassembling, changing accessories, or cleaning.
- Always wait until the motor comes to a complete stop before removing the Cup, Attachments, or when handling the unit.
- Do not place Cups, Attachments, and To-Go Lids in the microwave, they are not microwave safe.
- Do not store an exposed Rapid Extractor Blade on the Motor Base without attaching a Cup.
- NEVER place the Rapid Extractor Blade, Cups, Attachments or To-Go Lids on the bottom rack or use the heat/sanitize cycle of your dishwasher when cleaning. It may cause warping and possible safety hazards.
- Do not attempt to clean the Motor Base by immersing in water or other cleaning liquids. Gently wipe and dry with a clean cloth.
- Do not place any parts or accessories in a microwave, conventional oven, air fryer or stovetop pot, or immerse in boiling water to clean or sanitize, as this will damage the part.
- Make sure that the Motor Base ventilation areas are unobstructed and clean.
- Periodically inspect your nutribullet ® Ultra Plus+ components for damage or wear that may impair proper function or present a danger or safety hazard. Never operate your nutribullet ® Ultra Plus+ with damaged parts or components: - Discontinue use if you detect cracking, cloudiness, warping, or damage to the Cups or Processor Work Bowl. - Discontinue use if the Rapid Extractor Blade does not rotate freely, or if the gasket is missing or damaged. Continued use with a damaged blade or use inconsistent with these instructions may result in bodily injury, property damage, or damage to your unit.
- EVER attempt to use your nutribullet ® Ultra Plus+ if it malfunctions, dropped, appears to be damaged or compromised in any manner. Contact Customer Service for assistance at: 1 (800) 523-5993.
- Depending on use, it is recommended that the Rapid Extractor Blade be replaced at least every 5 years.
- NEVER use after-market replacement parts for your nutribullet ® Ultra Plus+. Aftermarket parts are not made to nutribullet ® specifications and may damage your unit or cause serious injury. Use only genuine nutribullet ® attachments/accessories specifically designed for your nutribullet ® Ultra Plus+ blender by calling Customer Service at: 1 (800) 523-5993.
